Interface Related Features

Interface Features — cont.

Host Transmission Buffers

Specifies the number of host transmission(s) that may be buffered. By buffering data from a bar code, the scanner can continue to read a new bar code while the old one is being transmitted to the host. Selecting BUFFERS = 1 means that the first bar code must be transmitted before a new one can be read. A selection of BUFFERS = 2 means that a new bar code can be read while data from the first bar code is transmitted.

When a DISABLE SCANNER command is received from the host, the scanner will continue to transmit all data that is buffered.

START / END

PROGRAMMING bar codes

Host Transmission Buffers = 1

Host Transmission Buffers = 2

DEFAULT

42

MagellanTM 3200VSi

Page 50
Image 50
Datalogic Scanning 3200VSI manual Interface Features, Host Transmission Buffers