Message

Causes

Corrective Actions

 

 

 

Warning! Power

The system configuration of

If any system components

required exceeds

processor(s), memory

were just upgraded,

PSU wattage.

modules, and expansion

return the system to the

Check PSU and

cards may not be supported

previous configuration. If

system

by the power supplies.

the system boots without

configuration.

 

this warning, then the

Warning!

 

replaced component(s) are

 

not supported with this

Performance

 

 

power supply. If Energy

degraded. CPU and

 

 

Smart power supplies are

memory set to

 

 

installed, replace them with

minimum

 

 

the High Output power

frequencies to

 

 

supplies to use the

meet PSU wattage.

 

 

components. See "Power

System will

 

 

Supplies" on page 77.

reboot.

 

 

 

 

 

 

Warning! PSU

A high output power supply

Install two high output

mismatch. PSU

and an Energy Smart power

or two Energy Smart power

redundancy lost.

supply are installed in the

supplies in the system.

Check PSU.

system at the same time.

You can also run the system

 

 

 

 

on one power supply until

 

 

you can obtain two power

 

 

supplies of the same type.

 

 

See "Troubleshooting Power

 

 

Supplies" on page 135.

 

 

 

Warning!

Invalid memory

Ensure that the memory

Unsupported

configuration. The system

modules are installed in a

memory

runs but with reduced

valid configuration.

configuration

functionality.

See "General Memory

detected. The

 

Module

memory

 

Installation Guidelines" on

configuration is

 

page 81. If the

not optimal. The

 

problem persists,

recommended

 

see "Troubleshooting System

memory

 

Memory" on page 137.

configuration

 

 

is: <message>

 

 