Message

Causes

Corrective Actions

 

 

 

Embedded NICx and

The OS NIC interface is set

Check the system

NICy:

in BIOS. The Management

management software or the

OS NIC=<ENABLED

Shared NIC interface is set

System Setup program for

DISABLED>,

in management tools.

NIC settings. If a problem is

Management

 

indicated, see

Shared NIC=

 

"Troubleshooting a NIC" on

<ENABLED

 

page 131.

DISABLED>.

 

 

Error 8602 - Auxiliary Device Failure. Verify that mouse and keyboard are securely attached to correct connectors.

Mouse or keyboard cable is

Reseat the mouse or

loose or improperly

keyboard cable.

connected.

 

Defective mouse or keyboard. Ensure that the mouse or keyboard is operational. See "Troubleshooting a USB Device" on page 130.

Gate A20 failure. Faulty keyboard controller;

See "Getting Help" on

 

faulty system board.

page 157.

 

 

 

Invalid

An invalid system

Run the System Setup

configuration

configuration caused a

program and review the

information -

system to stop responding.

current settings. See "Using

please run SETUP

 

the System Setup Program

program.

 

and UEFI Boot Manager" on

 

 

page 39.

 

 

 

Invalid PCIe card

The system halted because

Remove the PCIe expansion

found in the

an invalid PCIe expansion

card and install the

Internal_Storage

card is installed in the

integrated storage controller

slot!

dedicated storage controller

in the dedicated slot. See

 

slot.

"RAID Battery" on page 111.

 

 

 

Keyboard fuse has

Overcurrent detected at the

See "Getting Help" on

failed.

keyboard connector.

page 157.