Dell DL2200 Bios Update, Attempt Failed, Nvramclr jumper, Is installed on, CPU set to, Minimum

Models: DL2200

1 164
Download 164 pages 10.28 Kb
Page 24
Image 24

Message

Causes

Corrective Actions

 

 

 

BIOS Update

Remote BIOS update

Retry the BIOS update.

Attempt Failed!

attempt failed.

If problem persists,

 

 

see "Getting Help" on

 

 

page 157.

Caution!

NVRAM_CLR jumper is

NVRAM_CLR jumper

installed in the clear setting.

is installed on

CMOS has been cleared.

system board.

 

Please run SETUP.

 

Move the NVRAM_CLR jumper to the default position (pins 3 and 5). See Figure 6-1 for jumper location. Restart the system and re-enter the BIOS settings. See "Using the System Setup Program and UEFI Boot Manager" on page 39.

CPU set to

The processor speed may be

If not an intentional setting,

minimum

intentionally set lower for

check any other system

frequency.

power conservation.

messages for possible causes.

 

 

 

CPU x installed

Memory modules are

Install memory modules for

with no memory.

required but not installed in

the processor. See "System

 

the indicated processor’s

Memory" on page 80.

 

memory slots.

 