Dell E30S Expanded Operating Temperature, Non-redundant power supplies are not supported

Models: E30S

1 179
Download 179 pages 10.44 Kb
Page 176
Image 176
• Non-redundant power supplies are not supported.

Expanded Operating Temperature

Non-redundant power supplies are not supported.

• Cabled power supply units are not supported.

• Non Dell qualified peripheral cards and/or peripheral cards greater than 25 W are not supported.

Environmental

NOTE: For additional information about environmental measurements for specific system configurations, see dell.com/environmental_datasheets.

Temperature

Maximum Temperature Gradient (Operating and Storage)

Storage Temperature Limits

Relative Humidity

Storage

Temperature (Continuous Operation)

Temperature Ranges (for altitude less than 950 m or 3117 ft)

Humidity Percentage Range

Maximum Vibration

Operating

Storage

Maximum Shock

Operating

Storage

Maximum Altitude

Operating

Storage

20 °C/h (36 °F/h)

–40 °C to 65 °C (–40 °F to 149 °F)

5% to 95% RH with 33 °C (91 °F) maximum dew point. Atmosphere must be non-condensing at all times.

10 °C to 35 °C (50 °F to 95 °F) with no direct sunlight on the equipment.

10% to 80% Relative Humidity with 29 °C (84.2 °F) maximum dew point.

0.26Grms at 5 Hz to 350 Hz (all operation orientations).

1.88Grms at 10 Hz to 500 Hz for 15 min (all six sides tested).

Six consecutively executed shock pulses in the positive and negative x, y, and z axes of 40 G for up to 2.3 ms.

Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms.

3,048 m (10,000 ft)

12,000 m (39,370 ft).

176

Page 176
Image 176