PROBE PRECISION

 

 

 

 

 

GAUGE

ABSOLUTE

 

TEMPE-

 

 

 

 

 

 

DIFFERENTIAL

ABSOLUTE

RELATIVE

ABSOLUTE

 

 

 

 

 

Rated

Maximum

RELATIVE

ABSOLUTE

rear of sensor

rear of sensor

PRECISION

RATURE

WORKING

CONNECTIONS

 

pressure

over-pressure

rear of sensor

rear of sensor

connected to

connected to

20÷25°C

DRIFT

TEMP.

 

connected to

connected to

ambient

vacuum

AT 25°C

 

 

 

 

 

 

 

 

 

 

 

 

GATE 2

vacuum

INSULATED

INSULATED

 

%FS 1°C

 

 

 

 

 

 

 

 

MEMBRANE

MEMBRANE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10.0 mbar

20.0 mbar

TP705-10MBD

 

 

 

0.50% FSO

0.024

0÷60°C

i= 5 mm TUBE

 

20.0 mbar

40.0 mbar

TP705-20MBD

 

 

 

0.50% FSO

0.024

0÷60°C

i= 5 mm TUBE

 

50.0 mbar

100 mbar

TP705-50MBD

 

 

 

0.50% FSO

0.024

0÷60°C

i= 5 mm TUBE

 

100 mbar

200 mbar

TP705-100MBD

 

 

 

0.25% FSO

0.012

0÷60°C

i= 5 mm TUBE

 

 

 

 

 

 

 

 

 

 

 

 

 

200 mbar

400 mbar

TP705-200MBD

 

 

 

0.12% FSO

0.012

0÷60°C

i= 5 mm TUBE

 

 

 

 

 

TP704-200MBGI

 

0.20% FSO

0.015

0÷80°C

 

1/4 BSP

120

500 mbar

1000 mbar

TP705-500MBD

 

 

 

0.12% FSO

0.012

0÷60°C

i= 5 mm TUBE

 

 

 

 

TP704-500MBGI

 

0.20% FSO

0.015

0÷80°C

 

1/4 BSP

 

1.00 bar

2.00 bar

TP705-1BD

TP705BARO

 

 

0.12% FSO

0.012

0÷60°C

i= 5 mm TUBE

 

 

 

 

 

TP704-1 BGI

 

0.20% FSO

0.015

0÷80°C

 

1/4 BSP

 

2.00 bar

4.00 bar

TP705-2BD

 

 

 

0.12% FSO

0.012

0÷60°C

i= 5 mm TUBE

 

 

 

 

 

TP704-2BGI

TP704-2BAI

0.40% FSO

0.04

0÷80°C

 

1/4 BSP

 

10.0 bar

20.0 bar

 

 

TP704-10BGI

TP704-10BAI

0.40% FSO

0.04

0÷80°C

 

1/4 BSP

 

20.0 bar

40.0 bar

 

 

TP704-20BGI

TP704-20BAI

0.40% FSO

0.04

0÷80°C

 

1/4 BSP

 

50.0 bar

100.0 bar

 

 

TP704-50BGI

TP704-50BAI

0.40% FSO

0.04

0÷80°C

 

1/4 BSP

 

100 bar

200 bar

 

 

 

TP704-100BAI

0.40% FSO

0.04

0÷80°C

 

1/4 BSP

 

200 bar

400 bar

 

 

 

TP704-200BAI

0.40% FSO

0.04

0÷80°C

 

1/4 BSP

 

500 bar

750 bar

 

 

 

TP704-500BAI

0.50% FSO

0.04

0÷80°C

 

1/4 BSP

 

1000 bar

1100 bar

 

 

 

TP704-1000BAI

0.50% FSO

0.04

0÷80°C

 

1/4 BSP

N.B.: Differential probes may be used also for relative measurements (use only the socket marked +).

Differential probes may be used also for two-pole measurements (with pressure on the bottom socket marked + and pressure on the socket marked –). The BAROMETRIC probe may be used also for measurements up to 0 bar (vacuum).

ENGLISH