Break-in Procedure
CAUTION: Risk of property damage. Serious damage may result if the following
This procedure is required:
• | Before the air compressor is used for the first time. |
• | When the unloader valve has been replaced. |
• | When the compressor pump has been replaced. |
The procedure: | |
1. | Follow |
Electric Start
a. Remove cap from 18V battery pack (Q) and plug battery power pack into battery receptacle. Close battery cover over battery and lock
(U)into place, if desired (lock not included). NOTE: Make sure your battery pack is fully charged. See Charger Procedure for charging procedure.
Q |
| English |
| u | |
|
|
2. | Rotate the unloader's manual lock to the open position to |
| prevent air tank pressure buildup. |
3. | Open the pressure regulator. Pull regulator knob (F) out and rotate |
| clockwise until it stops. |
4. | Prepare engine for first time use, see engine's instruction manual |
| for correct procedure. |
5. | Place the fuel valve lever (O) in the ON postion. |
b. Place engine START/RUN/OFF switch (C) in the START position and hold until the engine starts.
NOTE: Do not hold the switch in the START position for more than 5 seconds. If the engine does not start, wait 10 seconds before retry- ing. Failure to follow these instructions may result in damage to the starter motor due to overheating.
c. When the engine starts, release the engine switch allowing it
6.If the engine is cold, move the choke (N) to the CLOSED position as shown. If the engine is hot, move the choke to the open position.
7.Recoil Start:
a.Turn the engine START/RUN/ OFF switch (C) to the RUN position.
closed | Open | |
| ||
n | ON | |
o | ||
| ||
OFF |
|
to return to the RUN position.
NOTE: Do not turn the engine switch to the START position while the engine is running.
Note: If the oil level in the engine is low, the engine will not start. If the engine does not start, check the oil level and add oil as needed.
NOTE: To ensure maximum oil lubrication, place the unit on a level surface.
8. As the engine warms up, move the choke to the open position. |
b.Warning: Risk of unsafe operation. Pull starter grip slowly until resistance is felt. Then pull starter grip (P) rapidly to avoid kickback and prevent hand or arm injury.
Note: Do not allow the starter grip to snap back. Return it gently by hand.
9. | Run the air compressor for 30 minutes to seat the rings and |
| lubricate all the internal surfaces. Ensure there is no pressure |
| build up in the air tank by observing the reading on the air tank |
| pressure gauge. |
10. | Rotate the manual lock on the unloader valve into the closed |
| position so the air tank pressure can build. |
19