HARSFEN0602ElmoHARmonicaSoftwareManual

PRELIMINARYDRAFT

12.1.6.5.1 The PVT Motion Programming Message

An entire row of the PVT table may be programmed by a single PDO.

The PDO used is 0x300+ID where ID is the node ID of the Amplifier.

Note that before using PDO 0x300+ID it must be mapped to the object 0x2001.

The mapping of this PDO for the PVT mode is listed in the table below.

Object Dictionary Index

0x2001

Type

RECORD, 3 elements

Access

Write only

Structure:

Signed32 Position

 

Signed24 Speed

 

Unsigned8 Time

PDO mapping

Yes

Value limits

No

Default value

Not Applicable

The PDO does not specify the PVT table row to be programmed. The row to be programmed is specified by a “write pointer”.

The parameter MP[6] initially sets the write pointer. A new PVT CANopen message (Object 0x2001) writes the data to the table row indicated by MP[6], and then automatically increments MP[6].

The CANopen auto increment mode has the following flow diagram:

148

Page 150
Image 150
Elmo HARmonica, HARSFEN0602 software manual 148, PVT Motion Programming Message