Elmo HARSFEN0602, HARmonica software manual 119, 32768

Models: HARmonica HARSFEN0602

1 220
Download 220 pages 51.63 Kb
Page 121
Image 121

HARSFEN0602ElmoHARmonicaSoftwareManual

 

 

PRELIMINARYDRAFT

 

106

log

XP[6]

Torque command filter bandwidth =

 

 

Hz where TS is the sampling time

2π ⋅ TS

32768

 

 

 

in usec.

The output the filter cannot change in steps greater than XP[5]. The units of XP[5] are internal torque command units, not Amperes. The ratio between the internal torque commands and Amperes is given by WS[22]. The role of XP[6] for small torque commands is plotted in the figure below.

Torque Cmd Vs. Torque Controller Input

 

300

 

 

 

 

 

 

 

250

 

 

XP[6]=4096

 

 

 

 

200

 

 

XP[6]=8196

 

 

 

 

 

 

 

 

 

 

Amp

150

 

XP[6]=16384

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100

 

 

 

 

 

 

 

50

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

0

2

4

6

8

10

12

 

 

 

Current Controller Sampling Times

 

 

Figure 12: Time constant selection (Small signal) for the torque input filter

The automatic current tuner of the Composer program optimizes the gains of the current controller for XP[6]=16000.

The parameter XP[6] is set to larger values for very high inductance motors, for which the current cannot rise rapidly, or if additional low-passing is required.

The role of XP[5] is shown in the figure below. In the example, the torque command is 5000 internal units (5000/WS[22] Amperes). XP[6] is set to its default of 16000.

XP[5] is factory-set to 1000.

Use lower values of XP[5] for very high inductance motors, for which the current cannot rise rapidly.

119

Page 121
Image 121
Elmo HARSFEN0602, HARmonica software manual 119, 32768