HARSFEN0602ElmoHARmonicaSoftwareManual

PRELIMINARYDRAFT

The following CAN emergencies are supported, all as manufacturer specific:

Error

Error

Reason

Data field

code

code

 

 

(Hex)

(Dec)

 

 

0x56

86

The queue is low: The number of yet

Field 1: Write pointer

 

 

unexecuted PVT table rows dropped below

Field 2: Read pointer

 

 

the value stated in MP[4]

 

0x5b

91

The write pointer is out of the physical

The value of MP[6]

 

 

[1,64] range of the PVT table. The reason

 

 

 

may be a bad setting of MP[6].

 

0x5c

92

The PDO 0x3xx is not mapped

 

0x34

52

Ann attempt has been made to program

Field 1:

 

 

more PVT points then there is place in the

The index of the PVT table

 

 

queue.

entry that could not be

 

 

 

programmed.

0x7

7

Cannot initialize motion due to bad setup

 

 

 

data. Reasons:

 

 

 

- The write pointer is outside the range

 

 

 

specified by the start pointer and the end

 

 

 

pointer.

 

0x8

8

Mode terminated, and the motor has been

Data field 1:

 

 

automatically stopped (In MO=1).

Write pointer

 

 

 

Data field 2:

 

 

 

1 for End of trajectory in non

 

 

 

cyclic mode

 

 

 

2 for A zero or negative time

 

 

 

specified for a motion interval

 

 

 

3 for Read pointer reached

 

 

 

write pointer

0x9

9

A CAN message has been lost.

.

Table 12-9 – PVT CAN Emergency Messages

152

Page 154
Image 154
Elmo HARmonica, HARSFEN0602 software manual 152