EMC Smarts Application Connectivity Monitor Configurat ion Guide 25
Specifying System Name Patterns
To specify the parameters for a Monitoring Action, perform the following
steps.
1Access the Application Signature tab.
2Enter a new application signature or select an existing signature from
the list at the top of the tab.
3At the Monitoring Action field, select the tcpAction.
4Click the Customize… button to display the parameters.
5Enter values for the parameters as necessary. The parameters marked in
red are required. In addition, the dialog box displays a message at the
bottom that lists required parameters that must be entered.
6Click the OK button.
7If the signature is disabled, click the Enable Checkbox.
8Click the Apply button.
Specifying System Name Patterns
System name matching patterns limit the discovery of applications to
selected systems in the topology of the ACM Domain Manager. This can be
important for large networks with many systems.
To specify system name patterns, click the Customize... button next to the
System Name Pattern field. This displays a dialog that provides two mutually
exclusive options:
Use all systems matched by pattern
Use only selected systems
Figure 4 illustrates the dialog.