Emerson 200I/48-NT5C05C Front panel LEDs, AC on ac voltage monitoring, CL current limit indicator

Models: 200I/48-NT5C05C

1 62
Download 62 pages 12.8 Kb
Page 34
Image 34

34 Functional description

4.2.3. Front panel LEDs

Table 10 - Designation of the LEDs on the front panel

LED

Color

Description

AC ON

Green

Input ac voltage operational

CL

Yellow

Current Limit

EQL

Yellow

Rectifier is in equalize mode

FAN ALM

Red

Fan fail alarm

HVSD

Red

High voltage shutdown

RFA

Red

Rectifier fail alarm

SEN FAIL

Red

Remote sense fail

THSD

Red

Thermal shutdown

AC ON ( ac voltage monitoring )

The rectifier monitors the input voltage and if the voltage exceeds the set limit, it will inhibit its operation and trigger a rectifier failure alarm

( RFA ). The rectifier will resume its normal operation automatically when the specified input voltage has been re-established.

CL ( current limit indicator )

This LED lights up if the rectifier is in current limit. The rectifier limits the output current to 205 A + 5 A ( adjusted in the factory ), 50% to 105% of the rated output current.

EQL ( equalize )

Indicates the rectifier is in equalizing mode.

FAN ALM ( fan failure alarm )

This LED lights up when the FAN ALM is activated due to a defect in the fan system. The fan configuration includes redundancy to ensure the rectifier will continue working properly if one of the fans fails. If only one fan fails, a rectifier failure alarm RFA will not be triggered. It is, however, imperative to repair or change the fan unit as soon as possible to preserve this redundant feature.

UM5C05C P0745680 Standard 6.00 October 2001

Emerson Energy Systems

Page 34
Image 34
Emerson 200I/48-NT5C05C user manual Front panel LEDs, AC on ac voltage monitoring, CL current limit indicator, EQL equalize