Rosemount 848L
Reference Manual
Table
Numbe |
|
|
r | Parameter | Description |
|
|
|
29 | TRANSDUCER_ TYPE_ | Identifies the transducer that follows. |
| 2 |
|
|
|
|
30 | XD_ ERROR_ 2 | One of the error codes defined in |
31 | COLLECTION_ | A directory that specifies the number, starting indices, and DD item IDs of the data collections in each |
| DIRECTORY_ 2 | transducer within a transducer block. For further information, please refer |
|
|
|
32 | IN_ 5_ TAG | An identifier associated with discrete input 5. |
33 | IN5 | The value and status of discrete input 5. |
|
|
|
34 | PULSE_ COUNT_ 5 | The number of pulses that have occurred on IN5 since last reset. |
35 | IN_ 5_ CONFIG.IO_TYPE | The transducer type of discrete sensor 5. |
|
|
|
35 | IN_ 5_ CONFIG.FILTER | Any state change on IN5 that lasts for a duration less than this filter value, will be ignored by the device. |
35 | IN_ 5_ CONFIG.FAIL_ | When the device detects a failure, IO5 will have its value set to this value. |
| SAFE |
|
|
|
|
36 | IN_ 6_ TAG | An identifier associated with discrete input 6. |
37 | IN6 | The value and status of discrete input 6. |
|
|
|
38 | PULSE_ COUNT_ 6 | The number of pulses that have occurred on IN6 since last reset. |
39 | IN_ 6_ CONFIG.IO_TYPE | The transducer type of discrete sensor 6. |
|
|
|
39 | IN_ 6_ CONFIG.FILTER | Any state change on IN6 that lasts for a duration less than this filter value, will be ignored by the device. |
39 | IN_ 6_ CONFIG.FAIL_ | When the device detects a failure, IO6 will have its value set to this value. |
| SAFE |
|
|
|
|
40 | IN_ 7_ TAG | An identifier associated with discrete input 7. |
41 | IN7 | The value and status of discrete input 7. |
|
|
|
42 | PULSE_ COUNT_ 7 | The number of pulses that have occurred on IN7 since last reset. |
43 | IN_ 7_ CONFIG.IO_TYPE | The transducer type of discrete sensor 7. |
|
|
|
43 | IN_ 7_ CONFIG.FILTER | Any state change on IN7 that lasts for a duration less than this filter value, will be ignored by the device. |
43 | IN_ 7_ CONFIG.FAIL_ | When the device detects a failure, IO7 will have its value set to this value. |
| SAFE |
|
|
|
|
44 | IN_ 8_ TAG | An identifier associated with discrete input 8. |
45 | IN8 | The value and status of discrete input 8. |
|
|
|
46 | PULSE_ COUNT_ 8 | The number of pulses that have occurred on IN8 since last reset. |
47 | IN_ 8_ CONFIG.IO_TYPE | The transducer type of discrete sensor 8. |
|
|
|
47 | IN_ 8_ CONFIG.FILTER | Any state change on IN8 that lasts for a duration less than this filter value, will be ignored by the device. |
47 | IN_ 8_ CONFIG.FAIL_ | When the device detects a failure, IO8 will have its value set to this value. |
| SAFE |
|
|
|
|
48 | TRANSDUCER_ TYPE_ | Identifies the transducer that follows. |
| 3 |
|
49 | XD_ ERROR_ 3 | One of the error codes defined in |
|
|
|
50 | COLLECTION_ | A directory that specifies the number, starting indices, and DD item IDs of the data collections in each |
| DIRECTORY_ 3 | transducer within a transducer block. For further information, please refer |
51 | OUT_ 1_ TAG | An identifier associated with discrete output 1. |
|
|
|
52 | OUT1 | The value and status of discrete Output 1. |
53 | OUT_ 1_ | The transducer type of discrete sensor 9. |
| CONFIG.IO_TYPE |
|
|
|
|
53 | OUT_ 1_ | Any state change that lasts for a duration less than this filter value, will be ignored by the device. |
| CONFIG.FILTER |
|
53 | OUT_ 1_ CONFIG.FAIL_ | When the device detects a failure, OUT1 will be set to this value. |
| SAFE |
|
|
|
|
54 | OUT_ 2_ TAG | An identifier associated with discrete output 2. |
55 | OUT2 | The value and status of discrete Output 2. |
|
|
|
56 | OUT_2_CONFIG.IO_TYP | The transducer type of discrete sensor 10. |
| E |
|
56 | OUT_ 2_ | Any state change that lasts for a duration less than this filter value, will be ignored by the device. |
| CONFIG.FILTER |
|
|
|
|
56 | OUT_2_CONFIG.FAIL_ | When the device detects a failure, OUT2 will be set to this value. |
| SAFE |
|
|
|
|