System Management: FRU LEDs
ATCA-9305 User’s Manual 10009109-01
7-22
Get FRU LED State Command

The Get FRU LED State command allows the state of the FRU LEDs to be controlled by the

management system.

Table 7-15: Get FRU LED State Command
Request Data 6 Color When Illuminated—sets the override color when LED Function
is 01h-FAh and FFh. Thi s byte sets the Local Cont rol color wh en LED
Function is FCh. This byte may be ignored during Lamp Test or may
be used to control the color during the lamp test when LED
Function is FBh.
Bits [7:4] reserved, set to 0
Bits [3:0]
0h reserved
1h Use Blue
2h Use Red
3h Use Green
4h Use Amber
5h Use Orange
6h Use White
7h-Dh reserved
Eh Do not change
Fh Use default color
Response Data 1 Completion Code
2 PICMG Identifier—indicates t hat this is a PICMG defined group
extension command. Use value 00h.
Type: Byte: Data Field:
Request Data 1 PICMG Identifier—indicates that this is a PICMG defined group
extension command. Use value 00h.
2 FRU Device ID
3LED ID
00h Blue LED (Hot Swap)
01h LED 1 (OOS)
02h LED 2
03h LED 3
04h-FEh OEM defined LEDs
FFh reserved
Response Data 1 Completion Code
2 PICMG Identifier—indicates t hat this is a PICMG defined group
extension command. Use value 00h.
Type: Byte: Data Field: (continued)