System Management: System Firmware Progress Sensor
10009109-01 ATCA-9305 User’s Manual 7-45

Get Message Listener List

The Get Message Listener List command returns the entire list of subscribed Message Lis-

teners. The command returns completion code (0x00) and IANA.

Table 7-44: Get Message Listener List Command

SYSTEM FIRMWARE PROGRESS SENSOR

The Update System Firmware Progress Sensor command sets the values for the Firmware

Progress Sensor using sensor codes from the IPMI Intelligent Platform Management Inter-

face Specification, specifically (System Firmware Progress” within Table 42-3 in Section 42.2

“Sensor Type Codes and Data.”

Type: Byte: Data Field:

Request Data 1:3 Emerson Network Power, Embedded Computing Inc. IANA Private
Enterprise ID
0x0065CD = 26061 (Emerson Network Power, Embedded
Computing Inc.)
LSB Byte first:byte 1 = CD, byte 2 = 65, byte 3 = 00
Response Data 1 Completion Code
2:4 Emerson Network Power, Embedded Computing Inc. IANA Private
Enterprise ID
0x0065CD = 26061 (Emerson Network Power, Embedded
Computing Inc.)
LSB Byte first:byte 2 = CD, byte 3 = 65, byte 4 = 00
5 Network function for listener 0
6 Command for listener 0
7 Network function for listener 1
8 Command for listener 1
9 Network function for listener 2
10 Command for listener 2
11 Network function for l istener 3
12 Command for listener 3
13 Network function for l istener 4
14 Command for listener 4
15 Network function for l istener 5
16 Command for listener 5
17 Network function for l istener 6
18 Command for listener 6
19 Network function for l istener 7
20 Command for listener 7