Commands by Subsystem 3

:TRIGger:LIN:TRIGger

Command Syntax

N O T E

(see page 530)

:TRIGger:LIN:TRIGger <condition>

<condition> ::= {SYNCbreak ID}

The :TRIGger:LIN:TRIGger command sets the LIN trigger on condition to be Sync Break (SYNCbreak) or Frame Id (ID).

The ID option is available when the automotive CAN and LIN serial decode option (Option AMS) has been licensed.

Query Syntax :TRIGger:LIN:TRIGger?

The :TRIGger:LIN:TRIGger? query returns the current LIN trigger value.

Return Format <condition><NL>

<condition> ::= {SYNC ID}

Errors "- 241, Hardware missing" on page 501

See Also "Introduction to :TRIGger Commands" on page 313

":TRIGger:MODE" on page 319

":TRIGger:LIN:SIGNal:DEFinition" on page 497

":TRIGger:LIN:SOURce" on page 368