:TRIGger:LIN:SIGNal:DEFinition

(see page 530)
Command Syntax :TRIGger:LIN:SIGNal:DEFinition <value>
<value> ::= {LIN | RX | TX}
The :TRIGger:LIN:SIGNal:DEFinition command sets the LIN signal type.
These signals can be set to:
Dominant low signals:
LIN — the actual LIN single- end bus signal line.
RX — the Receive signal from the LIN bus transceiver.
TX — the Transmit signal to the LIN bus transceiver.
Query Syntax :TRIGger:LIN:SIGNal:DEFinition?
The :TRIGger:LIN:SIGNal:DEFinition? query returns the current LIN signal
type.
Return Format <value><NL>
<value> ::= LIN
See Also "Introduction to :TRIGger Commands" on page 313
":TRIGger:MODE" on page 319
":TRIGger:LIN:SIGNal:BAUDrate" on page 367