206 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Reference
3Commands by Subsystem

:MARKer:X1Position

(see page 530)
Command Syntax :MARKer:X1Position <position> [suffix]
<position> ::= X1 cursor position in NR3 format
<suffix> ::= {s | ms | us | ns | ps | Hz | kHz | MHz}
The :MARKer:X1Position command sets :MARKer:MODE to MANual, sets
the X1 cursor position and moves the X1 cursor to the specified value.
Query Syntax :MARKer:X1Position?
The :MARKer:X1Position? query returns the current X1 cursor position. If
the front- panel cursors are off an error is returned. This is functionally
equivalent to the obsolete :MEASure:TSTArt command/query.
Return Format <position><NL>
<position> ::= X1 cursor position in NR3 format
See Also "Introduction to :MARKer Commands" on page 204
":MARKer:MODE" on page 205
":MARKer:X2Position" on page 208
":MARKer:X1Y1source" on page 207
":MARKer:X2Y2source" on page 209
":MEASure:TSTArt" on page 484