3Commands by Subsystem

:TRIGger:SPI:SOURce:FRAMe

(see page 530)

Command Syntax :TRIGger:SPI:SOURce:FRAMe <source>

<source> ::= {CHANnel<n> EXTernal} for the DSO models

<source> ::= {CHANnel<n> DIGital0,..,DIGital15} for the MSO models <n> ::= {1 2 3 4} for the four channel oscilloscope models <n> ::= {1 2} for the two channel oscilloscope models

 

The :TRIGger:SPI:SOURce:FRAMe command sets the frame source when

 

:TRIGger:SPI:FRAMing is set to CHIPselect or NOTChipselect.

Query Syntax

:TRIGger:SPI:SOURce:FRAMe?

 

The :TRIGger:SPI:SOURce:FRAMe? query returns the current frame source

 

for the SPI serial frame.

Return Format

<source><NL>

See Also

"Introduction to :TRIGger Commands" on page 313

 

":TRIGger:SPI:SOURce:CLOCk" on page 378

 

":TRIGger:SPI:SOURce:DATA" on page 379

 

":TRIGger:SPI:FRAMing" on page 375

380

Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Reference

Page 380
Image 380
Agilent Technologies 5000 Series manual TRIGgerSPISOURceFRAMe, TRIGgerSPIFRAMing on