Commands by Subsystem 3
Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Reference 355

:TRIGger:IIC Commands

Table 61 :TRIGger:IIC Commands Summary

Command Query Options and Query Returns
:TRIGger:IIC:PATTern:
ADDRess <value> (see
page 356)
:TRIGger:IIC:PATTern:
ADDRess? (see
page 356)
<value> ::= integer or <string>
<string> ::= "0xnn" n ::= {0,..,9
| A,..,F}
:TRIGger:IIC:PATTern:
DATA <value> (see
page 357)
:TRIGger:IIC:PATTern:
DATA? (see page 357)
<value> ::= integer or <string>
<string> ::= "0xnn" n ::= {0,..,9
| A,..,F}
:TRIGger:IIC:PATTern:
DATa2 <value> (see
page 358)
:TRIGger:IIC:PATTern:
DATa2? (see page 358)
<value> ::= integer or <string>
<string> ::= "0xnn" n ::= {0,..,9
| A,..,F}
:TRIGger:IIC[:SOURce]
:CLOCk <source> (see
page 359)
:TRIGger:IIC[:SOURce]
:CLOCk? (see
page 359)
<source> ::= {CHANnel<n> |
EXTernal} for DSO models
<source> ::= {CHANnel<n> |
DIGital0,..,DIGital15 } for MSO
models
<n> ::= 1-2 or 1-4 in NR1 format
:TRIGger:IIC[:SOURce]
:DATA <source> (see
page 360)
:TRIGger:IIC[:SOURce]
:DATA? (see page 360)
<source> ::= {CHANnel<n> |
EXTernal} for DSO models
<source> ::= {CHANnel<n> |
DIGital0,..,DIGital15 } for MSO
models
<n> ::= 1-2 or 1-4 in NR1 format
:TRIGger:IIC:TRIGger:
QUALifier <value>
(see page 361)
:TRIGger:IIC:TRIGger:
QUALifier? (see
page 361)
<value> ::= {EQUal | NOTequal |
LESSthan | GREaterthan}
:TRIGger:IIC:TRIGger[
:TYPE] <type> (see
page 362)
:TRIGger:IIC:TRIGger[
:TYPE]? (see
page 362)
<type> ::= {STARt | STOP | READ7
| READEprom | WRITe7 | WRITe10 |
NACKnowledge | ANACknowledge |
R7Data2 | W7Data2 | RESTart}