3Commands by Subsystem

:TRIGger:DURation:RANGe

Command Syntax

N O T E

(see page 530)

:TRIGger:DURation:RANGe <greater than time>[<suffix>], <less than time>[<suffix>]

<greater than time> ::= minimum duration in seconds

(10 ns - 9.99 seconds) in NR3 format

<less than time> ::= maximum duration in seconds

(15 ns - 10 seconds) in NR3 format

<suffix> ::= {s ms us ns ps}

The :TRIGger:DURation:RANGe command sets the duration for the defined pattern when the :TRIGger:DURation:QUALifier command is set to INRange or OUTRange.

If you set the minimum duration longer than the maximum duration, the order of the parameters is automatically reversed.

Query Syntax :TRIGger:DURation:RANGe?

The :TRIGger:DURation:RANGe? query returns the duration time for the defined pattern.

Return Format <greater than time>,<less than time><NL>

See Also "Introduction to :TRIGger Commands" on page 313

":TRIGger:DURation:PATTern" on page 338

":TRIGger:DURation:QUALifier" on page 339

":TRIGger:MODE" on page 319

340

Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Reference

Page 340
Image 340
Agilent Technologies 5000 Series manual TRIGgerDURationRANGe, Command Syntax