3Commands by Subsystem

:TRIGger:SPI:SOURce:CLOCk

(see page 530)

Command Syntax :TRIGger:SPI:SOURce:CLOCk <source>

<source> ::= {CHANnel<n> EXTernal} for the DSO models

<source> ::= {CHANnel<n> DIGital0,..,DIGital15} for the MSO models <n> ::= {1 2 3 4} for the four channel oscilloscope models <n> ::= {1 2} for the two channel oscilloscope models

 

The :TRIGger:SPI:SOURce:CLOCk command sets the source for the SPI

 

serial clock.

Query Syntax

:TRIGger:SPI:SOURce:CLOCk?

 

The :TRIGger:SPI:SOURce:CLOCk? query returns the current source for the

 

SPI serial clock.

Return Format

<source><NL>

See Also

"Introduction to :TRIGger Commands" on page 313

 

":TRIGger:SPI:CLOCk:SLOPe" on page 373

 

":TRIGger:SPI:CLOCk:TIMeout" on page 374

 

":TRIGger:SPI:SOURce:FRAMe" on page 380

 

":TRIGger:SPI:SOURce:DATA" on page 379

378

Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Reference

Page 378
Image 378
Agilent Technologies 5000 Series manual TRIGgerSPISOURceCLOCk, See Also