Commands by Subsystem 3

:TRIGger:DURation:QUALifier

(see page 530)

Command Syntax :TRIGger:DURation:QUALifier <qualifier>

<qualifier> ::= {GREaterthan LESSthan INRange OUTRange TIMeout}

The :TRIGger:DURation:QUALifier command qualifies the trigger duration.

Set the GREaterthan qualifier value with the :TRIGger:DURation:GREaterthan command.

Set the LESSthan qualifier value with the :TRIGger:DURation:LESSthan command.

Set the INRange and OUTRange qualifier values with the :TRIGger:DURation:RANGe command.

Set the TIMeout qualifier value with the :TRIGger:DURation:GREaterthan command.

Query Syntax :TRIGger:DURation:QUALifier?

The :TRIGger:DURation:QUALifier? query returns the trigger duration qualifier.

Return Format <qualifier><NL>

See Also "Introduction to :TRIGger Commands" on page 313

":TRIGger:DURation:GREaterthan" on page 336

":TRIGger:DURation:LESSthan" on page 337

":TRIGger:DURation:RANGe" on page 340

Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Reference

339

Page 339
Image 339
Agilent Technologies 5000 Series manual TRIGgerDURationQUALifier