390 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Reference
3Commands by Subsystem

:TRIGger:UART:BITorder

(see page 530)
Command Syntax :TRIGger:UART:BITorder <bitorder>
<bitorder> ::= {LSBFirst | MSBFirst}
The :TRIGger:UART:BITorder command specifies the order of transmission
used by the physical Tx and Rx input signals for the serial decoder and/or
trigger when in UART mode. LSBFirst sets the least significant bit of each
message "byte" as transmitted first. MSBFirst sets the most significant bit
as transmitted first.
Query Syntax :TRIGger:UART:BITorder?
The :TRIGger:UART:BITorder? query returns the current UART bit order
setting.
Return Format <bitorder><NL>
<bitorder> ::= {LSBF | MSBF}
See Also "Introduction to :TRIGger Commands" on page 313
":TRIGger:MODE" on page 319
":TRIGger:UART:TYPE" on page 399
":TRIGger:UART:SOURce:RX" on page 397
":TRIGger:UART:SOURce:TX" on page 398