Commands by Subsystem 3

:TRIGger:LIN:ID

(see page 530)

Command Syntax :TRIGger:LIN:ID <value>

<value> ::= 7-bit integer in decimal, <nondecimal>, or <string> from 0-63 or 0x00-0x3f

<nondecimal> ::= #Hnn where n ::= {0,..,9 A,..,F} for hexadecimal <nondecimal> ::= #Bnn...n where n ::= {0 1} for binary <string> ::= "0xnn" where n ::= {0,..,9 A,..,F} for hexadecimal

 

 

The :TRIGger:LIN:ID command defines the LIN identifier searched for in

 

 

each CAN message when the LIN trigger mode is set to frame ID.

 

 

This command is only valid when the automotive CAN and LIN serial decode option (Option

N O T E

 

 

AMS) has been licensed.

 

 

 

 

 

 

 

Setting the ID to a value of "- 1" results in "0xXX" which is equivalent to

 

 

all IDs.

Query Syntax

:TRIGger:LIN:ID?

 

 

The :TRIGger:LIN:ID? query returns the current LIN identifier setting.

Return Format

<value><NL>

 

 

<value> ::= integer in decimal

Errors

"- 241, Hardware missing" on page 501

See Also

"Introduction to :TRIGger Commands" on page 313

 

 

":TRIGger:MODE" on page 319

 

 

":TRIGger:LIN:TRIGger" on page 371

 

 

":TRIGger:LIN:SIGNal:DEFinition" on page 497

 

 

":TRIGger:LIN:SOURce" on page 368

Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Reference

365

Page 365
Image 365