5Obsolete and Discontinued Commands

:CHANnel<n>:INPut

(see page 530)

Command Syntax :CHANnel<n>:INPut <impedance> <impedance> ::= {ONEMeg FIFTy}

<n> ::= {1 2 3 4} for the four channel oscilloscope models <n> ::= {1 2} for the two channel oscilloscope models

 

The :CHANnel<n>:INPut command selects the input impedance setting for

 

the specified channel. The legal values for this command are ONEMeg (1

 

M) and FIFTy (50).

 

The :CHANnel<n>:INPut command is an obsolete command provided for compatibility to

N O T E

previous oscilloscopes. Use the :CHANnel<n>:IMPedance command (see page 148)

 

 

instead.

 

 

Query Syntax

:CHANnel<n>:INPut?

 

The :CHANnel<n>:INPut? query returns the current input impedance

 

setting for the specified channel.

Return Format

<impedance value><NL>

 

<impedance value> ::= {ONEM FIFT}

464

Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Reference

Page 464
Image 464
Agilent Technologies 5000 Series manual CHANnelnINPut, Instead