3Commands by Subsystem

:TIMebase:WINDow:POSition

 

(see page 530)

Command Syntax

:TIMebase:WINDow:POSition <pos value>

 

<pos value> ::= time from the trigger event to the delayed view

 

reference point in NR3 format

 

The :TIMebase:WINDow:POSition command sets the horizontal position in

 

the delayed view of the main sweep. The main sweep range and the main

 

sweep horizontal position determine the range for this command. The

 

value for this command must keep the delayed view window within the

 

main sweep range.

Query Syntax

:TIMebase:WINDow:POSition?

 

The :TIMebase:WINDow:POSition? query returns the current horizontal

 

window position setting in the delayed view.

Return Format

<value><NL>

 

<value> ::= position value in seconds

See Also

"Introduction to :TIMebase Commands" on page 302

 

":TIMebase:MODE" on page 304

 

":TIMebase:POSition" on page 305

 

":TIMebase:RANGe" on page 306

 

":TIMebase:SCALe" on page 308

 

":TIMebase:WINDow:RANGe" on page 311

 

":TIMebase:WINDow:SCALe" on page 312

310

Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Reference

Page 310
Image 310
Agilent Technologies 5000 Series manual TIMebaseWINDowPOSition, Query Syntax