3Commands by Subsystem

:MEASure:XMIN

(see page 530)

Command Syntax :MEASure:XMIN [<source>]

<source> ::= {CHANnel<n> FUNCtion MATH}

<n> ::= {1 2 3 4} for the four channel oscilloscope models <n> ::= {1 2} for the two channel oscilloscope models

The :MEASure:XMIN command installs a screen measurement and starts an X- at- Min- Y measurement on the selected window. If the optional source parameter is specified, the current source is modified.

N O T E

:MEASure:XMIN is an alias for :MEASure:TMIN.

 

Query Syntax

:MEASure:XMIN? [<source>]

 

The :MEASure:XMIN? query measures and returns the horizontal axis

 

value at which the minimum vertical value occurs. If the optional source is

 

specified, the current source is modified. If all channels are off, the query

 

returns 9.9E+37.

Return Format

<value><NL>

 

<value> ::= horizontal value of the minimum in NR3 format

See Also

"Introduction to :MEASure Commands" on page 218

 

":MEASure:XMAX" on page 255

 

":MEASure:TMIN" on page 483