3Commands by Subsystem

:TRIGger:CAN Commands

Table 57 :TRIGger:CAN Commands Summary

Command

Query

Options and Query Returns

 

 

 

:TRIGger:CAN:PATTern:

:TRIGger:CAN:PATTern:

<value> ::= 64-bit integer in

DATA <value>, <mask>

DATA? (see page 326)

decimal, <nondecimal>, or

(see page 326)

 

<string> (with Option AMS)

 

 

<mask> ::= 64-bit integer in

 

 

decimal, <nondecimal>, or

 

 

<string>

 

 

<nondecimal> ::= #Hnn...n where n

 

 

::= {0,..,9 A,..,F} for

 

 

hexadecimal

 

 

<nondecimal> ::= #Bnn...n where n

 

 

::= {0 1} for binary

 

 

<string> ::= "0xnn...n" where n

 

 

::= {0,..,9 A,..,F} for

 

 

hexadecimal

 

 

 

:TRIGger:CAN:PATTern:

:TRIGger:CAN:PATTern:

<length> ::= integer from 1 to 8

DATA:LENGth <length>

DATA:LENGth? (see

in NR1 format (with Option AMS)

(see page 327)

page 327)

 

 

 

 

:TRIGger:CAN:PATTern:

:TRIGger:CAN:PATTern:

<value> ::= 32-bit integer in

ID <value>, <mask>

ID? (see page 328)

decimal, <nondecimal>, or

(see page 328)

 

<string> (with Option AMS)

 

 

<mask> ::= 32-bit integer in

 

 

decimal, <nondecimal>, or

 

 

<string>

 

 

<nondecimal> ::= #Hnn...n where n

 

 

::= {0,..,9 A,..,F} for

 

 

hexadecimal

 

 

<nondecimal> ::= #Bnn...n where n

 

 

::= {0 1} for binary

 

 

<string> ::= "0xnn...n" where n

 

 

::= {0,..,9 A,..,F} for

 

 

hexadecimal

 

 

 

:TRIGger:CAN:PATTern:

:TRIGger:CAN:PATTern:

<value> ::= {STANdard EXTended}

ID:MODE <value> (see

ID:MODE? (see

(with Option AMS)

page 329)

page 329)

 

 

 

 

:TRIGger:CAN:SAMPlepo

:TRIGger:CAN:SAMPlepo

<value> ::= {60 62.5 68 70

int <value> (see

int? (see page 330)

75 80 87.5} in NR3 format

page 330)

 

 

 

 

 

:TRIGger:CAN:SIGNal:B

:TRIGger:CAN:SIGNal:B

<baudrate> ::= {10000 20000

AUDrate <baudrate>

AUDrate? (see

33300 50000 62500 83300

(see page 331)

page 331)

100000 125000 250000 500000

 

 

800000 1000000}

 

 

 

324

Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Reference

Page 324
Image 324
Agilent Technologies 5000 Series manual TRIGgerCAN Commands Summary