Commands by Subsystem 3

:MEASure:VAVerage

(see page 530)

Command Syntax :MEASure:VAVerage [<source>]

<source> ::= {CHANnel<n> FUNCtion MATH}

<n> ::= {1 2 3 4} for the four channel oscilloscope models <n> ::= {1 2} for the two channel oscilloscope models

The :MEASure:VAVerage command installs a screen measurement and starts an average value measurement. If the optional source parameter is specified, the current source is modified.

Query Syntax :MEASure:VAVerage? [<source>]

The :MEASure:VAVerage? query returns the average value of an integral number of periods of the signal. If at least three edges are not present, the oscilloscope averages all data points.

Return Format <value><NL>

<value> ::= calculated average value in NR3 format

See Also "Introduction to :MEASure Commands" on page 218

":MEASure:SOURce" on page 240

Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Reference