3Commands by Subsystem

:TRIGger:GLITch:LEVel

(see page 530)

Command Syntax :TRIGger:GLITch:LEVel <level_argument> <level_argument> ::= <level>[, <source>]

<level> ::= .75 x full-scale voltage from center screen in NR3 format for internal triggers

<level> ::= 2 V with probe attenuation at 1:1 in NR3 format for external triggers

<source> ::= {CHANnel<n> EXTernal}

<n> ::= {1 2 3 4} for the four channel oscilloscope models <n> ::= {1 2} for the two channel oscilloscope models

The :TRIGger:GLITch:LEVel command sets the trigger level voltage for the active pulse width trigger.

Query Syntax :TRIGger:GLITch:LEVel?

The :TRIGger:GLITch:LEVel? query returns the trigger level of the current pulse width trigger mode. If all channels are off, the query returns "NONE."

Return Format <level_argument><NL>

See Also "Introduction to :TRIGger Commands" on page 313

":TRIGger:MODE" on page 319

":TRIGger:GLITch:SOURce" on page 354