Commands by Subsystem 3
Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Reference 285

:SBUS:LIN:PARity

(see page 530)
Command Syntax :SBUS:LIN:PARity <display>
<display> ::= {{1 | ON} | {0 | OFF}}
The :SBUS:LIN:PARity command determines whether the parity bits are
included as the most significant bits (MSB) in the display of the Frame Id
field in the LIN decode bus.
Query Syntax :SBUS:LIN:PARity?
The :SBUS:LIN:PARity? query returns the current LIN parity bits display
setting of the serial decode bus.
Return Format <display><NL>
<display> ::= {0 | 1}
Errors "- 241, Hardware missing" on page 501
See Also "Introduction to :SBUS Commands" on page 277
":TRIGger:LIN Commands" on page 364
NOTE This command is only valid on 4 (analog) channel oscilloscope models when the
automotive CAN and LIN serial decode option (Option AMS) has been licensed.