3Commands by Subsystem

:TRIGger:LIN:SOURce

(see page 530)

Command Syntax :TRIGger:LIN:SOURce <source>

<source> ::= {CHANnel<n> EXTernal} for the DSO models

<source> ::= {CHANnel<n> DIGital0,..,DIGital15} for the MSO models <n> ::= {1 2 3 4} for the four channel oscilloscope models <n> ::= {1 2} for the two channel oscilloscope models

 

The :TRIGger:LIN:SOURce command sets the source for the LIN signal.

Query Syntax

:TRIGger:LIN:SOURce?

 

The :TRIGger:LIN:SOURce? query returns the current source for the LIN

 

signal.

Return Format

<source><NL>

See Also

"Introduction to :TRIGger Commands" on page 313

 

":TRIGger:MODE" on page 319

 

":TRIGger:LIN:TRIGger" on page 371

 

":TRIGger:LIN:SIGNal:DEFinition" on page 497

368

Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Reference

Page 368
Image 368
Agilent Technologies 5000 Series manual TRIGgerLINSOURce, See Also