REV. 5 7/6/2007

Liebert Monitoring Group –Development

Static Bypass Switch

 

 

 

 

 

 

 

 

 

 

Inverter

 

 

 

 

 

 

 

 

 

 

Communication Fail

 

10281

 

 

 

 

 

 

 

 

Rectifier

 

 

 

 

 

 

 

 

 

 

Communication

 

 

 

 

 

 

 

 

 

 

Failure

 

10282

 

 

 

 

 

 

 

 

Parallel

 

10283

 

 

 

 

 

 

 

 

Communication Fault

 

 

 

 

 

 

 

 

 

Operation Fault

 

10289

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Data Point

 

Input Register

 

Holding Register

 

# of Reg.

 

Scale

 

 

 

 

 

 

 

 

 

Notes / Units

Number of Input

 

 

 

 

 

 

 

 

 

 

Lines

 

30004

 

40004

 

1

 

1

Bits 12 - 15

Number of Bypass

 

 

 

 

 

 

 

 

 

 

Lines

 

30004

 

40004

 

1

 

1

 

Bits 4 - 7

Number of Output

 

30004

 

40004

 

1

 

1

Bits 8 - 11

Lines

 

 

 

 

Number Of

 

30009

 

40009

 

1

 

 

 

 

SubModules

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

There are 16 possible

 

 

 

 

 

 

 

 

 

 

Load Circuits. So

 

 

 

 

 

 

 

 

 

 

each bit represents 1

 

 

 

 

 

 

 

 

 

 

load circuit. Load

 

 

 

 

 

 

 

 

 

 

Circuit 1 is bit 0, Load

 

 

 

 

 

 

 

 

 

 

Circuit 2 is bit 1 and

 

 

 

 

 

 

 

 

 

 

so on. If the bit is 1

 

 

 

 

 

 

 

 

 

 

then the Load Circuit

Load Circuit Present

 

30013

 

40013

 

1

 

 

 

is supported.

Module Number

 

30014

 

40014

 

1

 

 

 

 

Device Module Count

 

30015

 

40015

 

1

 

 

 

 

Device Redundant

 

 

 

 

 

 

 

 

 

 

Count

 

30016

 

40016

 

1

 

 

 

 

Device Module Mode

 

30017

 

40017

 

1

 

 

 

 

Nominal Power

 

 

 

 

 

 

 

 

 

 

Rating

 

30021

 

40021

 

2

 

 

 

VA

Nominal Input

 

 

 

 

 

 

 

 

 

 

Voltage

 

30027

 

40027

 

1

 

 

V

Nominal Output

 

30028

 

40028

 

1

 

 

 

 

Voltage

 

 

 

 

 

 

V

Nominal Static

 

 

 

 

 

 

 

 

 

 

Bypass Switch

 

 

 

 

 

 

 

 

 

 

Voltage

 

30029

 

40029

 

1

 

 

V

Nominal Input

 

 

 

 

 

 

 

 

 

 

Frequency

 

30031

 

40031

 

1

 

10

 

Hz

Nominal Output

 

 

 

 

 

 

 

 

 

 

Frequency

 

30032

 

40032

 

1

 

10

 

Hz

Nominal Power

 

 

 

 

 

 

 

 

 

 

Factor

 

30033

 

40033

 

1

 

100

 

 

Nominal DC Bus #1

 

 

 

 

 

 

 

 

 

 

Voltage

 

30035

 

40035

 

1

 

 

V

Nominal DC Bus #2

 

 

 

 

 

 

 

 

 

 

Voltage

 

30036

 

40036

 

1

 

 

 

 

9

Page 12