Emerson OpenComms-485 manual HourMinute Sleep Interval 30042 40042 MSBHr

Models: OpenComms-485

1 39
Download 39 pages 12.67 Kb
Page 36
Image 36

REV. 5 7/6/2007

Liebert Monitoring Group –Development

Hour:Minute

 

 

 

 

 

 

 

Sleep Interval 2

30042

40042

1

 

MSB:Hr

U607(FROM)

 

Start Time

 

 

 

 

 

 

 

Hour:Minute

 

 

 

 

 

 

 

Sleep Interval 2

30043

40043

1

 

MSB:Hr

U607(TO)

End Time

 

 

 

 

 

 

 

Hour:Minute

 

 

 

 

 

 

 

Timer Dead Band

 

30044

40044

1

X10

U611

 

Manual VSD

30045

40045

1

 

 

 

 

Timer/Counter[6]

 

 

 

 

 

 

 

High

30050

40050

1

X10

U203

 

Temperature

 

 

 

 

 

 

 

Low Temperature

30051

40051

1

X10

U204

High

30052

40052

1

X10

U208

 

Temperature

 

 

 

 

 

 

 

Sensor A

 

 

 

 

 

 

 

Low Temperature

30053

40053

1

X10

U209

Sensor A

 

 

 

 

 

 

 

High Humidity

 

30054

40054

1

1

%

U205

 

Low Humidity

30055

40055

1

1

%

U206

High Humidity

30056

40056

1

1

%

U210

 

Sensor A

 

 

 

 

 

 

 

Low Humidity

30057

40057

1

1

%

U211

Sensor A

 

 

 

 

 

 

 

Fan Run Hour

30070

40070

 

1

Hour

U502

 

Threshold

 

 

 

 

 

 

 

Compressor 1

30071

40071

 

1

Hour

U503

Run Hour

 

 

 

 

 

 

 

Threshold

 

 

 

 

 

 

 

Compressor 2

30072

40072

 

1

Hour

U504

 

Run Hour

 

 

 

 

 

 

 

Threshold

 

 

 

 

 

 

 

Humidifier run

30073

40073

 

1

Hour

U510

hours Threshold

 

 

 

 

 

 

 

Dehumidification

30074

40074

 

1

Hour

U511

 

run hours

 

 

 

 

 

 

 

Threshold

 

 

 

 

 

 

 

CW/FC run hours

30075

40075

 

1

Hour

U505

Threshold

 

 

 

 

 

 

 

Electrical Heaters

30076

40076

 

1

Hour

U507

 

#1 run hours

 

 

 

 

 

 

 

Threshold

 

 

 

 

 

 

 

Electrical Heaters

30077

40077

 

1

Hour

U508

#2 run hours

 

 

 

 

 

 

 

Threshold

 

 

 

 

 

 

 

Electrical Heaters

30078

40078

 

1

Hour

U509

 

#3 run hours

 

 

 

 

 

 

 

Threshold

 

 

 

 

 

 

 

Hot Water / Hot

30079

40079

 

1

Hour

U506

Gas run hours

 

 

 

 

 

 

 

Threshold

 

 

 

 

 

 

 

Operating State

30100

-

 

1

-

EnvState.

 

[7]

 

 

 

 

 

 

OperatingState

 

Number of Active

30101

-

 

-

-

EnvState.

33

Page 36
Image 36
Emerson OpenComms-485 manual HourMinute Sleep Interval 30042 40042 MSBHr