Environmental and Power Requirements

 

 

3.Remove the desiccant bag shipped together with the blade and dispose of it according to your country’s legislation.

The product is thoroughly inspected before shipment. If any damage occurred during transportation or any items are missing, please contact our customer's service immediately.

2.3Environmental and Power Requirements

The following environmental and power requirements are applicable to the board.

2.3.1Environmental Requirements

Table 2-1 Environmental Requirements

Requirement

Operating

Non-Operating

 

 

 

Temperature

+5ºC (41ºF) to +40ºC (104ºF) (normal operation)

-40ºC (-40ºF) to +70ºC

 

according to NEBS Standard GR-63-CORE

(158ºF) (may be further

 

-5ºC to +55ºC (short term operation) according to

limited by installed

 

accessories)

 

NEBS Standard GR-63-CORE

 

 

 

 

 

Temp. Change

+/- 0.25ºC/min or 15ºC/h (59ºF/h) according to

+/- 0.25ºC/min or 15ºC/h

 

NEBS Standard GR-63-CORE

(59ºF/h)

 

 

 

Rel. Humidity

5% to 85% non-condensing according to Emerson

5% to 85% non-condensing

 

Network Power Embedded Computing-internal

according to Emerson

 

environmental requirements

Network Power Embedded

 

 

Computing-internal

 

 

environmental

 

 

requirements

 

 

 

Altitude

<= 4000m

 

 

 

 

Vibration

1.0g from 5 to 100 Hz and back to 5 Hz at a rate

5-20 Hz @ 0.01 g2/Hz

 

of 0.1 octave/minute

20-200 Hz @ -3.0

 

 

 

 

dB/octave

 

 

Random 5-20 Hz @ 1

 

 

m2/Sec3

 

 

Random 20-200 Hz @ -3

 

 

m/Sec2

Shock

Half-sine, 11 m/Sec, 30mSec/sec2

Blade level packaging

 

 

Half-sine, 6 mSec at 180

 

 

m/Sec2