Emerson manual Installing RTM-ATCA-7350

Models: RTM-ATCA-7350

1 52
Download 52 pages 12.63 Kb
Page 31
Image 31

Installing RTM-ATCA-7350

Hardware Preparation and Installation

 

 

The blue LED blinks indicating that the shelf manager is informed about the desire of the blade to power down the payload of the front blade and the power-down process is ongoing.

3.Wait until the blue LED of the front blade is permanently ON. A permanently switched ON LED indicates that the payload of the front blade has been powered down.

4.Remove the front blade. For instructions on how to remove the blade, refer to Section 2.7.2.2 Removing the ATCA-7350in ATCA-7350 Installation and Use manual.

5.Take RTM-ATCA-7350 out of the antistatic package.

6.Fully open the upper and lower ejector handles of the RTM.

7.Align the upper and lower sides of RTM-ATCA-7350 with the guide rails (the edges of the slot). Slide RTM-ATCA-7350 along the guide rails until the positioning pins of RTM-ATCA-7350 are inserted in the positioning holes in the shelf.

Figure 2-5 Installing RTM-ATCA-7350

8.Make sure that the ejector handles are fastened to the beam. Close the upper and lower ejector handles inwards until the inner sides of the ejector handles are attached to the face plate.

9.Use the screwdriver to fasten the captive screws clockwise to fix RTM-ATCA-7350. The LEDs of the RTM are off now.

RTM-ATCA-7350 Installation and Use (6806800H30F)

31