Hardware Preparation and Installation

Removing RTM-ATCA-7350

 

 

10.Insert the main blade. For instructions on how to install the main blade, refer to Section 2.7.1.1 Installing the ATCA-7350 in a Powered Shelf in ATCA-7350 Installation and Use manual.

11.Close the handles of the front blades. The LEDs; OOS LED, Blue LED, and healthy LED of RTM are on.

12.Wait until the blue LED on the RTM is OFF.

A switched off blue LED indicates that the payload of the RTM has become active.

2.7.2Removing RTM-ATCA-7350

Product Damage

You should power off the front blade before removing RTM-ATCA-7350.

To remove RTM-ATCA-7350, proceed as follows:

1.Wear the ESD-preventive wrist strap. For more information refer, Wearing the ESD- Preventive Wrist Strap on page 21.

2.Unlatch the lower handle outward by squeezing the lever and the latch together and turning the handle outward only enough to unlatch the handle from the face plate, that means until you feel a resistance. Do not rotate the handle fully outward.

The blue LED blinks indicating that the shelf manager is informed about the desire of the blade to power down the payload of both the front blade and the RTM and the power-down process in ongoing.

3.Wait until the blue LED of the RTM is permanently ON. A permanently switched ON LED indicates that the payload of the RTM has been powered down.

4.As shown in step 2 of the figure below, use the screwdriver to unfasten the captive screws of the RTM anticlockwise.

5.As shown in step 1 of the figure below, fully open the upper and lower ejector handles.

32

RTM-ATCA-7350 Installation and Use (6806800H30F)

Page 32
Image 32
Emerson manual Hardware Preparation and Installation Removing RTM-ATCA-7350