Connecting to the Network

Figure 3-19 Cable Connection to LC Fiber-Optic Connectors

43

 

44

 

45

 

46

 

47

 

48

 

47

45

 

46

 

47

 

48

 

C2G124-

 

48P

Â

 

À

Console

 

Á

Ã

1

Mini-GBIC MT-RJ port connector

3

Release tab

2

LC cable connector

4

Link/Activity LED

3.Plug the other end of the cable into the appropriate port on the other device. Some cables may be terminated at the other end with two separate connectors, one for each fiber‐optic strand. In this case, ensure that the transmit fiber‐optic strand is connected to the receive port and the receive fiber‐optic strand to the transmit port.

4.Verify that a link exists by checking that the port Link/Activity LED is on (blinking green or solid green). If the Link/Activity LED is off, perform the following steps until it is on:

a.Verify that the device at the other end of the segment is ON and connected to the segment.

b.If there are separate fiber‐optic connections on the other device, check the crossover of the cables. Swap the cable connections if necessary.

c.Check that the fiber‐optic connection meets the dB loss and cable specifications outlined in the Cabling Guide for multimode mode cabling. To obtain this document, refer to “Related Documents” on page xvi.

d.If a link has not been established, refer to Chapter 4 for LED troubleshooting details. If a problem persists, refer to “Getting Help” on page 1‐7 for details on contacting Enterasys Networks for support.

5.Repeat steps 1 through 4, above, until all connections have been made.

SecureStack C2 Installation Guide 3-29

Page 61
Image 61
Enterasys Networks C2H124-48P, C2G124-48P manual Cable Connection to LC Fiber-Optic Connectors