Using the Reset Button
Table
Problem | Possible Cause | Recommended Action |
|
|
|
Port(s) goes into | Loop condition detected. | Verify that Spanning Tree is enabled. Refer to the |
standby for no |
| SecureStack C2 Configuration Guide for the instructions to |
apparent reason. |
| set the type of STA. |
|
| Review the network design and delete unnecessary loops. |
|
| If the problem continues, contact Enterasys Networks for |
|
| technical support. |
|
|
|
User parameters | Clear NVRAM was set using | Reenter the lost parameters as necessary. Refer to the |
(IP address, device | CLI commands. | SecureStack C2 Configuration Guide for the instructions to |
and module name, |
| configure the switch using CLI commands. |
etc.) were lost |
| If the problem continues, contact Enterasys Networks for |
when the switch |
| |
| technical support. | |
power was cycled. |
| |
|
| |
|
|
|
Using the Reset Button
If you forget the switch login password, use the Reset button as described in the following procedure.