Enterasys Networks C2G124-48P, C2H124-48P manual Mgbic

Models: C2H124-48P C2G124-48P

1 82
Download 82 pages 21.48 Kb
Page 68
Image 68

Using LANVIEW

Table 4-1 LANVIEW LED Diagnostic Indications (continued)

LED

Color

State

Recommended Action

 

 

 

 

 

Link/

Off

1.

No link.

None.

Activity

 

2.

No activity or port in standby.

None.

(RJ45

 

 

3.

The port is deactivated because the

None.

PoE ports

 

 

 

Mini-GBIC port with the same port number

 

1–48)

 

 

 

 

 

is linked.

 

 

 

 

 

 

 

 

 

 

Green

Solid. Port is linked, but the interface is not

None.

 

 

receiving any traffic. PoE power is okay.

 

 

 

 

 

 

 

Blinking. Port is linked and traffic is being

None.

 

 

received or transmitted by the interface. PoE

 

 

 

power is okay.

 

 

 

 

 

 

Amber

Solid. Port is linked, but traffic is not being

1. Check the attached powered device

 

 

received or transmitted by the interface. PoE

to see if it is defective.

 

 

power has failed.

2. Internal power supply failed, contact

 

 

PoE power may have been deactivated because

 

 

Enterasys Networks for technical

 

 

of excessive power requirement or deactivated

support.

 

 

by configuration.

 

 

 

Power Supply failed.

 

 

 

 

 

 

 

Blinking. Port is linked and traffic is being

1. Check the attached powered device

 

 

received or transmitted by the interface. PoE

to see if it is defective.

 

 

power has failed.

2. Internal power supply failed, contact

 

 

PoE power may have been deactivated because

 

 

Enterasys Networks for technical

 

 

of excessive power requirement or deactivated

support.

 

 

by configuration.

 

 

 

Power supply failed.

 

 

 

 

 

 

Link/

Off

1.

No link.

None.

Activity

 

2.

No activity or port in standby.

None.

(MGBIC

 

 

3.

The port is deactivated because the RJ45

None.

ports 45–

 

 

 

port with the same port number is linked.

 

48)

 

 

 

 

 

 

 

 

Green

Solid. Port is linked, but the interface is not

None.

 

 

receiving any traffic.

 

 

 

 

 

 

 

Blinking. Port is linked and traffic is being

None.

 

 

received or transmitted by the interface.

 

 

 

 

 

 

4-6 Troubleshooting

Page 68
Image 68
Enterasys Networks C2G124-48P, C2H124-48P manual Mgbic