DIP Switch Settings

DIP switch 1

 

 

 

SW

Description

ON

OFF

 

 

 

 

 

 

 

 

 

 

1-1

 

 

Condensed mode on/off

Condensed

Normal

 

 

 

 

 

 

 

 

 

 

1-2

 

 

Slashed zero on/off

Slashed

Not slashed

 

 

 

 

 

 

 

 

 

 

1-3

 

 

Character table (in Epson ESClP mode)

Graphics

Italics

 

 

 

 

 

 

 

 

 

 

 

 

l-4

Printer mode

IBM emulation

Epson ESClP

 

 

 

 

 

 

 

 

 

 

 

 

I-5

NLCI or draft mode

NLQ

Draft

 

 

 

 

 

 

 

 

 

 

 

 

l-6

International character set

 

 

 

 

 

 

 

 

 

 

 

 

 

I-7

See table to the right.

 

 

 

(available only in Epson ESClP mode)

 

 

 

 

 

 

 

 

 

 

 

I-8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIP switch 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW

Description

ON

OFF

 

 

 

 

 

 

 

 

 

 

 

 

2-I

Default character set

User-defined

ROM

 

 

 

fin Eoson ESClP mode)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 2-2

1

Draft printing speed

Normal

Hiah

 

 

 

 

 

 

 

 

 

 

 

2-3

 

 

Bit length for serial interface

7 bits

8 bits

 

 

 

 

 

 

 

 

 

 

2-4

 

 

Auto line feed

ON

OFF

 

 

 

 

 

 

 

 

 

 

2-5

 

 

Interface type/parity

See table to the right.

 

 

 

 

 

 

 

 

2-6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2-7

 

 

Baud rate

See table to the right.

 

 

 

 

 

 

 

 

2-8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIP switch 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW

Description

ON

OFF

 

 

 

 

 

 

 

 

 

 

 

 

3-l

Input buffer

Invalid

Valid

 

 

 

 

 

 

 

 

 

 

 

3-2

 

Page length

12 inches

11 inches

 

 

 

 

 

 

 

 

 

 

3-3

 

l-inch skip over perforation

ON

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3-4

 

Paper memory

Memory 2

Memory 1

 

 

 

 

 

 

 

 

 

 

 

3-5

 

Overlapping multi-part forms

Valid

Invalid

 

 

 

 

 

 

 

 

 

 

 

3-6

 

Multi-part forms with labels

Valid

Invalid

 

 

 

 

 

 

 

 

 

 

 

3-7

 

Skip over binding

ON

OFF

 

 

 

 

 

 

 

 

 

 

3-8

 

Handshaking protocol

X-on/X-off

DTR