EXTERNAL CHANGER CONNECTIONS

EXTERNAL CHANGER CONNECTIONS

There are a few general rules to follow when connecting changers to

your FireBall...

Changer Types

Sony DVP-CX777ES DVD/CD (DVDs and CDs ONLY)

Sony 200, 300, 400 disc CDP Series CD changers (CDs ONLY)

Note: Sony CD and DVD/CD changers can not be mixed Different models of Sony CD changers may be mixed

Control Connections

Changer 1 should be connected to COM port 1

Changer 2 should be connected to COM port 2

Etc.

Note: Do NOT connect any S-Link cables from the FireBall to the Sony 777ES changers.

Digital Audio Connections

Changer 1 should be connected to Optical Digital in 1

Changer 2 should be connected to Optical Digital in 2

Etc.

Analog Audio Connections

Changer 1 should be connected to Analog Audio in 1

Changer 2 should be connected to Analog Audio in 2

Etc.

Sony DVD/CD Changer Hookup

Sony DVP-CX777ES 400 disc changers must be connected via individual RS-232 cables (not S-Link cables).

An RS-232 cable is standard a DB9 null modem cable (not included with the changer)

The analog audio connection is required when recording from external changers

Set each changer to address Command Mode 1.