Extron electronic DMP 64 manual EX1,X1!NG

Models: DMP 64

1 146
Download 146 pages 26.3 Kb
Page 108
Image 108
EX1),X1!NG}
EZQQQ}
Similar to System Reset,
plus sets the IP address to 192.168.254.254
and the subnet mask to 255.255.0.0.
Zpq]
EZY}
Zpy]

Command and Response table for basic SIS commands (continued)

Command

ASCII command

Response

Additional description

 

(host to device)

(device to host)

 

 

 

 

 

 

 

 

 

Presets, I/O Names

 

 

 

Write preset name

EX1),X1!NG}

NmgX1),X1!]

 

Example:

E1,Security1NG}

Nmg01,Security1]

Name preset 1 “Security 1”

Read preset name

EX1)NG}

X1!]

 

Example:

E2NG}

Security2]

 

Recall a preset

X1).

RprX1)]

Command character is a

 

 

 

period.

Example

5.

RprX1)]

Recall preset 5, which

 

 

 

becomes the current

 

 

 

configuration.

Write input name

EX#,X1!NI}

NmiX#,X1!]

 

Example:

E9,Podium cam1NI}

Nmi09,Podium cam1]

Name input 9 “Podium cam1”

Read input name

EX#NI}

X1!]

 

Write output name

EX@,X1!NO}

NmoX@,X1!]

 

Example:

E1,Main PJ1NO}

Nmo01,Main PJ1]

Name output 1 “Main PJ1”

Read output name

EX@NO}

X1!]

 

 

 

 

 

Resets

 

 

 

Reset presets and names

EZG}

Zpg]

Clear all presets and their

 

 

 

names.

Reset an individual preset

EX1)ZG}

ZpgX1)]

Clear preset X1).

Reset a group

EZX2)GRPM}

GrpmZX2)]

Delete all members from

 

 

 

group X2), reset parameters

 

 

 

and soft limits.

NOTE: See Group Masters on page 69, for more information about audio group masters.

Reset flash

EZFFF}

Zpf]

Reset flash memory

 

 

 

(erase user-supplied files).

System Reset (factory

EZXXX}

Zpx]

Resets all processors, level

defaults)

 

 

controls and mixers to default.

Reset all device settings and delete files

NOTE: This reset excludes IP settings such as IP address, subnet mask, gateway IP address, unit name, DHCP setting and port mapping (telnet/web/direct access) in order to preserve communication with the device.

This reset is recommended after a firmware update. Absolute reset

 

 

NOTES: X# = Input number

01 – 06

X@ = Output number

01 – 04

X1)

= Preset #

32 maximum (0 = current configuration)

X1! = Name

12 characters maximum

X2)

= Group master group number

01 – 32

 

 

 

DMP 64 • SIS Programming and Control

102

Page 108
Image 108
Extron electronic DMP 64 manual EX1,X1!NG