Change the Output Volume Level

Change the Output Volume Level

The output volume attenuates the signal from full volume down to 0 volume in 100 steps. Users can set individual output volume levels from a range of –100 dB (full attenuation, minimum volume) to 0 dB (no attenuation, full volume).

Change an output audio level setting as follows:

1.Next to the desired output number, click the output level drop-down box. A drop‑down list box appears.

2.Click and drag the slider or click the scroll up Change an output audio level setting as follows: button or scroll down Group Controls Page button until the desired audio level is visible.

Alternately the + and - boxes increment the level up or down one step.

3.Click the desired attenuation value. The range is –100 to 0 dB.

4.Repeat steps 1 through 3 for each output.

Group Controls Page

If group controls have been set using SIS commands or DSP Configurator, the group controls page provides access to those controls (see figure 73). Group controls cannot be set using the HTML pages. Access the group controls page by clicking the Group Controls link on the left of the control page.

Figure 73. Group Controls Page

To adjust a group control:

Next to the desired group control, directly input a value by clicking in the box and typing a value, or use the + and – box to increment or decrement the value by one.

Repeat for each group.

NOTE: The range of each group control is displayed under the value box.