Extron electronic DMP 64 manual FBS Dynamic Filters Tab

Models: DMP 64

1 146
Download 146 pages 26.3 Kb
Page 49
Image 49
FBS Dynamic Filters

FBS Dynamic Filters

This tab contains the fifteen dynamic filters, with a scroll bar to display filters hidden due to dialog box size.

Dynamic filters are notch filters that are cut only, providing attenuation up to 30 dB at the specified Q. The default Q is set in the Tools>Options menu, but can be changed on the settings tab prior to engaging the FBS dynamic filters. Changing the Q setting after dynamic filters have been generated clears all dynamic filters.

Figure 34. FBS Dynamic Filters Tab

Frequency and cut values are read only. Dynamic filters are in auto-detect mode when the FBS block is active (when BypassFBS is off). If testing reaches a point where no further changes are desired, the lock button can be engaged. The lock mode of operation is temporary, and is intended to be used during setup of the FBS. When the FBS dialog box is closed, lock mode is automatically disengaged.

If there are specific dynamic filters the user wants to assure are not overwritten, press the Move to Fixed button to write the designated filter settings to the first available filter in the Fixed Filter tab.

NOTE: When a dynamic filter setting is moved to the fixed filter, it automatically clears that frequency from the dynamic filter.

The Clear button removes a detected frequency from the corresponding dynamic filter. A cleared filter reverts to auto-detect mode unless Lock mode is engaged.

DMP 64 • Software Control

43

Page 49
Image 49
Extron electronic DMP 64 manual FBS Dynamic Filters Tab