The Presets page is used to save new presets created on the Audio Settings page (see figure 74). Presets saved using this HTML page only include the gain controls on that page. However, presets created using DSP Configurator include all signal processing blocks. When saving a preset from the HTML page, be certain not to overwrite those presets created by DSP Configurator.

Figure 74. Presets

To recall a preset to be the current configuration, click the button associated with the desired preset.

NOTE: When presets are recalled using the HTML page, signal processing adjustments saved as part of the preset (under DSP Configurator control only) are recalled and overwrite the current audio settings.

When a partial preset is recalled, it overwrites that portion of the current configuration addressed by the preset, leaving the remainder unchanged.

Special Characters

The HTML language reserves certain characters for specific functions. The device will not accept these characters as part of preset names, the device name, passwords, or locally created file names.

The device rejects the following characters:

{space} + ~ , @ = ‘ [ ] { } < > ’ " ; : > \ ?