Extron electronic MAV Plus Series manual Pinging to determine the Web IP address

Models: MAV Plus Series

1 186
Download 186 pages 11.96 Kb
Page 163
Image 163

4. At the DOS prompt, type ping {IP address} and then press Enter . The computer returns a display similar to as shown below.

The line Pinging ... reports the actual numeric IP address, regardless of whether you entered the actual numeric IP address or an alias name.

C:\>ping 192.168.254.254

Pinging 192.168.254.254 with 32 bytes of data:

Reply from 192.168.254.254: bytes=32 time<10ms TTL=128

Reply from 192.168.254.254: bytes=32 time<10ms TTL=128

Reply from 192.168.254.254: bytes=32 time<10ms TTL=128

Reply from 192.168.254.254: bytes=32 time<10ms TTL=128

Ping statistics for 192.168.254.254:

Packets: Sent = 4, Received = 4, Lost = 0 (0% loss),

Approximate round trip times in milli-seconds:

Minimum = 0ms, Maximum = 0ms, Average = 0ms

Pinging to determine the Web IP address

The Ping utility has a modifier, -a, that directs the command to return the Web address rather than the numeric IP address.

At the DOS prompt, type ping -a {IP address} and then press Enter . The computer’s return display is similar to the Ping response shown in the figure above, except that when you specify the -amodifier, the line Pinging mail... reports the web IP address rather than the numeric IP address, regardless of whether you entered the actual numeric IP address or an alias name.

Configuring the matrix switcher BME for network use via the ARP command

The ARP (address resolution protocol) command tells your computer to associate the matrix switcher BME’s MAC (media access control) address with the assigned IP address. You must then use the ping utility to access the controller, at which point the controller’s IP address is reconfigured.

Use ARP to configure the IP address as follows:

1.Obtain a valid IP address for the matrix switcher BME from your network administrator.

2.Obtain the BME’s MAC address (UID #) from the label on its rear panel. The MAC address should have this format: 00-05-A6-xx-xx-xx.

3.If the matrix switcher BME has never been configured and is still set for factory defaults, proceed to step 4. If not, perform a Mode 4 system reset and then proceed to step 4. For detailed information on reset modes, see “Performing soft system resets (reset modes 3, 4, and 5)” in chapter 3, “Operation”.

NThe matrix switcher BME must be configured with the factory default IP address (192.168.254.254) before the ARP command is executed, as described on the next page.

CrossPoint 450 Plus and MAV Plus Switchers • Ethernet Connection

A-3

Page 163
Image 163
Extron electronic MAV Plus Series manual Pinging to determine the Web IP address

MAV Plus Series specifications

Extron Electronics is a leading manufacturer of professional AV system integration solutions. Among its wide range of products, the MAV Plus Series and Ultra Series stand out for their advanced features and innovative technologies, catering to the needs of audio-visual professionals in various environments.

The MAV Plus Series, designed for efficient and flexible audio routing, provides reliable performance in various applications. It is characterized by its high-quality audio signal processing capabilities, which are essential for delivering clear and precise sound. One of the notable features of this series is the built-in audio mixing, allowing users to easily combine multiple audio sources. The MAV Plus Series supports both analog and digital audio formats, ensuring compatibility with a wide range of equipment.

Incorporating Extron's advanced technology, the MAV Plus Series features signal management tools that include automatic mixing, feedback suppression, and equalization. These tools not only enhance sound quality but also simplify the user experience, enabling quick adjustments in dynamic environments such as conference rooms, classrooms, and live events.

On the other hand, the Ultra Series is designed for users seeking high-performance audio routing and control in more demanding applications. This series is known for its robust construction and scalability, allowing for expansion as the needs of the organization grow. The Ultra Series offers an extensive range of inputs and outputs, including HDMI, which supports high-definition audio and video signals.

Ultra Series products are equipped with Extron's proprietary technologies like EDID Minder and Key Digital™, which ensure seamless compatibility and signal integrity between various devices. Additionally, the Ultra Series utilizes Ethernet control for centralized management, providing users with real-time monitoring and the ability to make adjustments remotely.

Both the MAV Plus and Ultra Series reflect Extron Electronics commitment to innovation and quality in the audio-visual space. They include user-friendly interfaces, making setup and operation straightforward even for those with limited technical expertise. With their comprehensive features, both series cater to professional AV installations, offering solutions that meet the needs of diverse applications across education, corporate, and entertainment sectors.

Investing in Extron’s MAV Plus and Ultra Series guarantees high-quality performance, adaptability, and long-term reliability, making them indispensable tools for audio-visual integration professionals.