Example 5: Grouping inputs and outputs

In the following example, several switcher inputs and outputs are assigned to groups. The steps show the front panel indications that result from your actions.

1. Clear all selections: Press and release the Esc button.

Press the Esc button to clear all selections.

C O N T R O L

ENTER PRESET VIEW ESC

The button flashes once.

2. Select I/O Group mode: Press and hold the Input 1 and Output 1 buttons for approximately 2 seconds and then release the buttons.

Press and hold the Input 1 button and Output 1 button.

1 2 1718

1 2 1718

Release the Input 1 button and Output 1 button.

I

1

N

 

2 seconds

 

Ungrouped input and

1

output buttons light.

 

O

 

U

 

3. Select an I/O group: Press and release the Enter button to select group 1.

Press and release the Enter button to select group 1.

The button lights to indicate the selection.

C O N T R O L

ENTER PRESET VIEW ESC

Group # 1

2

3

4

4. Assign inputs and outputs: Press and release the input 1 through 4 and output 1 through 4 buttons.

Press and release the Input 1 through Input 4 buttons. The selected buttons light.

1 2 3 4 5 6 7 8

1718192021222324

I

N

Press and release the Output 1 through Output 4 buttons. The selected buttons light.

1 2 3 4 5 6 7 8

1718192021222324

O U

CrossPoint 450 Plus and MAV Plus Switchers • Operation 3-25