Rear Panel Operations

The rear panel has a Reset button that initiates four levels of resets (numbered 1, 3, 4, and 5 for the sake of comparison with an Extron IPL product). The Reset button is recessed, so use a pointed stylus, ballpoint pen, or small screwdriver to access it.

See the following table for a summary of the modes.

CReview the reset modes carefully. Using the wrong reset mode may result in unintended loss of flash memory programming, port reassignment, or a controller reboot.

NThe reset modes listed below close all open IP and Telnet connections and close all sockets. Also, the following modes are separate functions, not a continuation from mode 1 to mode 5.

Reset Mode Comparison/Summary

Mode

Activation

 

Result

Purpose/Notes

 

 

 

 

1

Hold down the recessed Reset button

The switcher reverts to the factory default

Use mode 1 to revert

 

while applying power to the switcher.

firmware. Event scripting does not start if the

to the factory default

 

N After a mode 1 reset is

switcher is powered on in this mode. All user files

firmware version if

 

and settings, such as IP settings, are maintained.

incompatibility issues

 

performed, update the switcher’s

N If you do not want to update firmware, or

arise with user-loaded

 

firmware to the latest version.

firmware.

 

Do not operate the switcher

 

if you performed a mode 1 reset by mistake,

 

 

 

 

firmware version that results

 

cycle power to the switcher to return to the

 

 

from the mode 1 reset. If you

 

firmware version that was running before the

 

 

want to use the factory default

 

mode 1 reset. Use the 0Q SIS command to

 

 

firmware, you must upload that

 

confirm that the factory default firmware is

 

 

version again. See chapter 5,

 

no longer running (look for the asterisk [*]

 

 

“Matrix Software”, for details

 

following the version number.

 

 

on uploading firmware.

 

 

 

 

 

 

 

3

Hold down the Reset button for about

Mode 3 turns events on or off. During resetting,

Mode 3 is useful for

 

3 seconds, until the Reset LED blinks

the Reset LED flashes two times if events are

troubleshooting.

 

once, then press Reset momentarily

starting, three times if events are stopping.

 

 

(<1 second) within 1 second.

 

 

 

 

 

 

 

4

Hold down the Reset button for

Mode 4:

Mode 4 enables you

 

about 6 seconds, until the Reset LED

Enables ARP capability.

to set IP address

 

blinks twice (once at 3 seconds and

• Sets the IP address to the factory default.

information using ARP

 

again at 6 seconds). Then press Reset

• Sets the subnet address to the factory default.

and the MAC address.

 

momentarily (<1 second) within 1

• Sets the gateway address to the factory default.

 

 

second.

• Sets port mapping to the factory default.

 

 

 

Turns DHCP off.

 

 

 

Turn events off.

 

 

 

The Reset LED flashes four times in quick

 

 

 

succession during the reset.

 

 

 

 

 

5

Hold down the Reset button for

Mode 5 performs a complete reset to factory

Mode 5 is useful if

 

about 9 seconds, until the Reset LED

defaults (with the exception of the firmware):

you want to start over

 

blinks three times (once at 3 seconds,

• Does everything mode 4 does.

with configuration and

 

again at 6 seconds, and then again

• Resets most settings including:

uploading or to replace

 

at 9 seconds). Then press Reset

 

Clears all ties and presets.

events.

 

momentarily (<1 second) within 1

 

Clears all output mutes.

Same as EZQQQ}

 

second.

 

Clears all I/O grouping.

SIS command,

 

 

• Resets all IP options.

see chapter 4,

 

 

• Removes/clears all files for the switcher.

“Programmer’s

 

 

The reset LED flashes four times in quick

Guide“.

 

 

succession during the reset.

 

For different reset levels, press and hold the button while the switcher is running or press and hold the button while you apply power to the switcher.

CrossPoint 450 Plus and MAV Plus Switchers • Operation 3-47

Page 79
Image 79
Extron electronic MAV Plus Series manual Rear Panel Operations, Reset Mode Comparison/Summary

MAV Plus Series specifications

Extron Electronics is a leading manufacturer of professional AV system integration solutions. Among its wide range of products, the MAV Plus Series and Ultra Series stand out for their advanced features and innovative technologies, catering to the needs of audio-visual professionals in various environments.

The MAV Plus Series, designed for efficient and flexible audio routing, provides reliable performance in various applications. It is characterized by its high-quality audio signal processing capabilities, which are essential for delivering clear and precise sound. One of the notable features of this series is the built-in audio mixing, allowing users to easily combine multiple audio sources. The MAV Plus Series supports both analog and digital audio formats, ensuring compatibility with a wide range of equipment.

Incorporating Extron's advanced technology, the MAV Plus Series features signal management tools that include automatic mixing, feedback suppression, and equalization. These tools not only enhance sound quality but also simplify the user experience, enabling quick adjustments in dynamic environments such as conference rooms, classrooms, and live events.

On the other hand, the Ultra Series is designed for users seeking high-performance audio routing and control in more demanding applications. This series is known for its robust construction and scalability, allowing for expansion as the needs of the organization grow. The Ultra Series offers an extensive range of inputs and outputs, including HDMI, which supports high-definition audio and video signals.

Ultra Series products are equipped with Extron's proprietary technologies like EDID Minder and Key Digital™, which ensure seamless compatibility and signal integrity between various devices. Additionally, the Ultra Series utilizes Ethernet control for centralized management, providing users with real-time monitoring and the ability to make adjustments remotely.

Both the MAV Plus and Ultra Series reflect Extron Electronics commitment to innovation and quality in the audio-visual space. They include user-friendly interfaces, making setup and operation straightforward even for those with limited technical expertise. With their comprehensive features, both series cater to professional AV installations, offering solutions that meet the needs of diverse applications across education, corporate, and entertainment sectors.

Investing in Extron’s MAV Plus and Ultra Series guarantees high-quality performance, adaptability, and long-term reliability, making them indispensable tools for audio-visual integration professionals.